180 Ah battery backup time

How long a 12 V 180 Ah tubular inverter battery runs at different loads, alone and as a 24 V pair.

  • About 8 h 25 min at 200 W
  • About 3 h 35 min at 400 W

One 180 Ah battery (12 V inverter)

A fully charged, healthy battery. At 400 W it discharges at about 0.23C, against the C20 (0.05C) its Ah is rated at, so it gives less than the label.

LoadBackupExample
50 W34 h 35 minWi-Fi and two lights
100 W17 h 20 minA fan and three lights
150 W11 h 30 min
200 W8 h 25 minTwo fans, four lights, TV
250 W6 h 30 min
300 W5 h 10 minThree fans, lights, TV, Wi-Fi
400 W3 h 35 minThree fans, six lights, TV, Wi-Fi
500 W2 h 35 minAdd the fridge
600 W2 hFour fans, lights, TV, fridge
800 W1 h 10 minA big house, or a cooler

Two 180 Ah batteries (24 V inverter)

The usual set-up for 1.5 kVA and 2 kVA inverters.

LoadBackup (2 batteries, 24 V)
300 W11 h 30 min
400 W8 h 25 min
500 W6 h 30 min
600 W5 h 10 min
800 W3 h 35 min
1000 W2 h 35 min
1200 W2 h
1500 W1 h 20 min

180 Ah models we list

Specs as stated on each manufacturer’s page. Sorted by brand; we don’t rank them.

ModelTypeWarrantyMaker’s backup at 400 W
Exide FEM0-IMTT1800tall tubularNot stated—
Livguard IT1872TTtall tubular72 months (48 free replacement + 24 pro-rata)—
Microtek Dura Strong M1803624TTtall tubular60 months (36 free replacement + 24 pro-rata)—

Method: watt-hours at 12 V × the share lead-acid delivers at that current, fitted to V-Guard’s published 400 W backup table, ÷ load. Checked against Exide’s Inva Zen tables, which it matches within about 10% from 200 to 400 W and undershoots at 100 W. Real backup falls as the battery ages.