260 Ah battery backup time
How long a 12 V 260 Ah tubular inverter battery runs at different loads, alone and as a 24 V pair.
- About 12 h 30 min at 200 W
- About 5 h 40 min at 400 W
Inputs, results, working, link and sources, on your device.
One 260 Ah battery (12 V inverter)
A fully charged, healthy battery. At 400 W it discharges at about 0.16C, against the C20 (0.05C) its Ah is rated at, so it gives less than the label.
| Load | Backup | Example |
|---|---|---|
| 50 W | 49 h 55 min | Wi-Fi and two lights |
| 100 W | 25 h | A fan and three lights |
| 150 W | 16 h 35 min | |
| 200 W | 12 h 30 min | Two fans, four lights, TV |
| 250 W | 9 h 55 min | |
| 300 W | 8 h 05 min | Three fans, lights, TV, Wi-Fi |
| 400 W | 5 h 40 min | Three fans, six lights, TV, Wi-Fi |
| 500 W | 4 h 20 min | Add the fridge |
| 600 W | 3 h 25 min | Four fans, lights, TV, fridge |
| 800 W | 2 h 10 min | A big house, or a cooler |
Two 260 Ah batteries (24 V inverter)
The usual set-up for 1.5 kVA and 2 kVA inverters.
| Load | Backup (2 batteries, 24 V) |
|---|---|
| 300 W | 16 h 35 min |
| 400 W | 12 h 30 min |
| 500 W | 9 h 55 min |
| 600 W | 8 h 05 min |
| 800 W | 5 h 40 min |
| 1000 W | 4 h 20 min |
| 1200 W | 3 h 25 min |
| 1500 W | 2 h 30 min |